MaxBESS
THE ALL IN ONE STORAGE SOLUTION

MaxBESS, THE ALL-IN-ONE SYSTEM CONSISTING OF: INVERTER, BATTERIES, BMS AND ENERGY MANAGEMENT SYSTEM.

Thanks to its very compact dimensions it is the ideal system for installations in commercial and industrial contexts, but also for larger power systems given the modularity and flexibility of installation.

MaxBESS MAIN FEATURES:

• Storage capacity of 72 kWh
• Integrated PCS with power up to 70 kW
• LFP batteries for longer life and safety
• Monitoring with local interface
• Remote access via web server
• Modular system with a wide range of
configurations

CERTIFICATO CEI 0-21 e CEI 0-16


SELF CONSUMPTION OPTIMIZATION

PEAK SHAVING

BACK-UP POWER

MICRO GRID

OFF GRID / ON GRID

TIME OF USE

GENSET OPTIMIZATION

POWER QUALITY

ALL IN ONE SOLUTION

1
2
3
4
5
1

MAIN PANEL

IN-BUILT EMS

With power meter

AC MAIN SWITCH

Disconnector

TYPE 2 / CLASS II

Surge protection device

2

RACK PCS

Withdrawable PCS (with quick fit connectors) Up to 70 kW

3

BATTERY MANAGEMENT SYSTEM

With precharge circuit, insulation monitoring and CAN comunication

4

TERMINALS

Feed through terminals for power cables connections and external signal/command AC sockets

5

BATTERY MODULE

5,12 kWh LFP battery with integrated fan, for total 71.68 KWh each cabinet

WIDE RANGE OF CONFIGURATIONS

For systems with greater capacity and power, it is possible to increase the units in parallel upon request

HIGH FLEXIBILITY OF INSTALLATION AND INTEGRATION WITH ON-GRID AND OFF-GRID SYSTEMS

EEI MaxBESS allows to be easily integrated in on-grid systems as an All-in-one Energy Storage unit, reducing at maximum all efforts needed to integrate different type of batteries, BMSs and PCSs. The fast and intuitive installation permit to easily integrate energy storage in your plant and immediatly benefit from all the in-built functionalities of EEI MaxBESS

EEI MaxBESS can be easily integrated in off-grid systems as an All-in-one Energy Storage unit, where it works as main source or in parallel with other sources as PV inverters or generators to support at best the reliability of the system. All in-built functionalities can be used to create the most efficient and fast responsive energy supply in your off-grid plant.

MaxBESS REFLECT THE CORE OF ITALIAN DESIGN AND INNOVATION

Max Bess is designed, produced, and tested internally at our headquarters in Vicenza, Italy. We are committed to providing our customers with the highest level of satisfaction by offering reliable, efficient, and safe products.

EEI remotely supports its customers by connecting via the network to its products and by sending spare parts in a timely manner from the warehouse located in Italy.

MONITORING EEI ENERGY MANAGEMENT SYSTEM IN BUILT EMS DETAILS

All data can be monitored, controlled and recorded with EEI energy management system consisting of in-built EMS. By setting dedicated control logic, you can combine a wide variety of functionalities to perfectly adapt the system to your needs.

LOCAL INTERFACE & IN-BUILT EMS:

• Data acquisition and optimised energy flows
Generation, load and storage system control
• Local user interface with different views for complete configuration of the system.
Integrated three phase meter for grid monitoring and control.
Remote monitoring, service and maintainence through EEI Energy Portal.

TECHNICAL DETAILS

MAX BESS – Brochure

CONTACT US NOW TO GET A PREVIEW OF PRICE AND COMPATIBILITY

If you are an installer, we are sure that MaxBESS will be the best option for you.

Price, design and compatibility make it ideal for all situations.

CERTIFICATO CEI 0-21 e CE0-16